発電機
発電機容量(kVA) | 10.5/13 | 20/25 | 37/45 | 50/60 | 75/90 | 80/100 | 100/125 | 125/150 | 195/220 | 270/300 | 350/400 | 450/500 | 550/600 | 700/800 | 1,000/1 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
25%負荷時消費量 負荷(kW) | 2.2/2.6 | 4/5 | 7.4/9 | 10/12 | 15/18 | 16/20 | 20/25 | 25/30 | 39/44 | 54/60 | 70/80 | 90/100 | 110/120 | 140/160 | 200/220 |
25%負荷時消費量 L/h | 1.4/1.7 | 1.6/2.0 | 3.1/4.0 | 4.1/5.3 | 5.9/7.7 | 6.1/7.6 | 7.1/9.4 | 7.7/10.1 | 13.4/16.7 | 15.4/19.0 | 22.5/28.9 | 29.6/37.3 | 34.8/45.6 | 43.3/56.3 | 63.2/78.5 |
50%負荷時消費量 負荷(kW) | 4.2/5.2 | 8/10 | 14.8/18 | 20/24 | 30/36 | 32/40 | 40/50 | 50/60 | 78/88 | 108/120 | 140/160 | 180/200 | 220/240 | 280/320 | 400/440 |
50%負荷時消費量 L/h | 1.8/2.3 | 2.4/3.0 | 4.7/5.8 | 6.4/8.0 | 9.1/11.3 | 9.6/12.4 | 11.3/14.4 | 13.1/15.9 | 21.8/25.8 | 26.7/31.6 | 38.4/47.8 | 49.6/59.9 | 59.3/71.3 | 73.6/90.9 | 108/125 |
75%負荷時消費量 負荷(kW) | 6.3/7.8 | 12/15 | 22.2/27 | 30/36 | 45/54 | 48/60 | 60/75 | 75/90 | 117/132 | 162/180 | 210/240 | 270/300 | 330/360 | 420/480 | 600/660 |
75%負荷時消費量 L/h | 2.4/2.9 | 3.3/4.2 | 6.6/8.1 | 8.9/10.6 | 12.5/15.5 | 13.5/17.4 | 15.7/19.8 | 18.3/22.4 | 32.0/35.7 | 39.0/47.0 | 54.8/67.4 | 71.6/85.9 | 82.0/96.4 | 103/125 | 154/180 |
100%負荷時消費量 負荷(kW) | 8.4/10.4 | 16/20 | 29.6/36 | 40/48 | 60/72 | 64/80 | 80/100 | 100/120 | 156/176 | 216/240 | 280/320 | 360/400 | 440/480 | 560/640 | 800/880 |
100%負荷時消費量 L/h | 3.1/3.8 | 4.4/5.6 | 8.7/10.8 | 11.6/14.1 | 16.4/20.4 | 18.0/23.1 | 20.2/26.5 | 24.4/28.8 | 41.5/46.5 | 52.7/62.7 | 69.8/89.0 | 92.4/112.4 | 109/126 | 138/165 | 206/232 |